Veolia Water Systems
Two-Stage Biological Odour Control System for Tilal City Sewage Treatment Plant, Sharjah
Project Overview
ERG Air Pollution Control supplied a two-stage odour control system for Veolia Water Systems at Tilal City Sewage Treatment Plant (STP) in Sharjah, United Arab Emirates.
Delivered in 2019 for end-user Tilal Properties LLC, the installation was designed to treat odorous air generated by sewage treatment operations, combining a biotrickling filter with an activated carbon polishing stage.
The odour control unit (OCU) was designed for an airflow of 16,000 m³/hr and an inlet hydrogen sulphide (H₂S) concentration of 157 ppm, with a specified removal efficiency exceeding 99.9%.
ERG’s scope included the design, material supply and manufacturing of the treatment system.
The project demonstrates ERG’s experience in providing high-efficiency biological odour control systems for municipal wastewater infrastructure in the Middle East.
The Challenge – Hydrogen Sulphide Emissions from Wastewater Treatment
Sewage treatment facilities can generate odorous gases as organic matter breaks down during wastewater collection and treatment.
Hydrogen sulphide is a particularly important contaminant because of its characteristic rotten-egg odour, toxicity and potential to contribute to corrosion within wastewater infrastructure.
At Tilal City STP, the odour control system was required to treat an airflow of 16,000 m³/hr containing a specified inlet H₂S concentration of 157 ppm.
The project called for a two-stage treatment arrangement capable of achieving greater than 99.9% hydrogen sulphide removal.
Effective odour control is particularly important for wastewater facilities located near developing residential and commercial areas, where emissions may affect neighbouring communities.
The treatment system therefore needed to combine substantial airflow capacity with a high level of hydrogen sulphide removal.
ERG’s Solution – Biotrickling Filtration and Carbon Polishing
ERG supplied a two-stage odour control unit incorporating a biotrickling filter followed by activated carbon filtration.
Stage One – Biological Treatment
The first stage uses biotrickling filtration to remove hydrogen sulphide from the contaminated air stream.
Biotrickling filters use microorganisms growing on a suitable support medium to biologically oxidise contaminants such as hydrogen sulphide.
As the odorous air passes through the filter, contaminants transfer into the wetted biofilm, where microorganisms convert them into oxidation products.
A circulating liquid helps maintain suitable conditions for biological activity and contaminant removal.
Biological odour control offers an established treatment approach for wastewater applications where hydrogen sulphide is a principal contaminant.
Stage Two – Activated Carbon Polishing
The second stage incorporates activated carbon filtration to provide additional odour treatment.
Activated carbon uses adsorption to retain suitable gaseous contaminants within its porous structure.
In a two-stage odour control system, carbon filtration can provide a polishing function following the primary biological treatment stage.
The performance of activated carbon depends on factors including contaminant composition, concentration, humidity, residence time and media selection.
The combination of biotrickling filtration and carbon polishing provides complementary treatment mechanisms within a single odour control arrangement.
ERG’s Scope of Supply
The original project case sheet identifies ERG’s scope as:
System design: Engineering the two-stage odour control arrangement.
Material supply: Providing materials for the treatment system.
Manufacturing: Fabrication and manufacture of the specified equipment.
Biotrickling filter: Primary biological treatment stage.
Carbon polishing filter: Secondary treatment stage for additional odour removal.
The original record does not specify whether installation and commissioning were included in ERG’s contractual scope.
Project Specifications
| Parameter | Project detail |
|---|---|
| Client | Veolia Water Systems |
| End-user | Tilal Properties LLC |
| Site | Tilal City STP, Sharjah, UAE |
| Application | Municipal wastewater odour control |
| Design airflow | 16,000 m³/hr |
| Inlet H₂S concentration | 157 ppm |
| Specified H₂S removal efficiency | >99.9% |
| Primary treatment | Biotrickling filter |
| Secondary treatment | Activated carbon polishing |
| ERG scope | Design, material supply and manufacturing |
| Year delivered | 2019 |
Biological Odour Control for Municipal Wastewater Treatment
Biotrickling filtration is widely used for the treatment of hydrogen sulphide and other suitable biodegradable odorous compounds generated by wastewater infrastructure.
Potential applications include sewage treatment works, pumping stations, sludge processing facilities and other municipal wastewater installations.
Where high removal efficiencies are required, biological treatment can be combined with activated carbon polishing to provide an additional treatment stage.
The appropriate system configuration depends on airflow, inlet contaminant concentrations, required outlet conditions and the characteristics of the wastewater facility.
The Tilal City project illustrates how biological and adsorption technologies can be integrated into a high-capacity odour control system.
ERG’s Wastewater Odour Control Experience
ERG Air Pollution Control designs and supplies engineered odour control systems for municipal and industrial wastewater applications.
Its treatment technologies include biotrickling filters, biofilters, activated carbon filtration and chemical wet scrubbing systems.
The Veolia Water Systems project at Tilal City STP demonstrates ERG’s capability to provide two-stage biological and carbon odour treatment systems for wastewater infrastructure in the United Arab Emirates.
Delivered in 2019, the installation forms part of ERG’s portfolio of international wastewater odour control projects.
For further information about biotrickling filters, activated carbon polishing or wastewater odour control systems, contact ERG Air Pollution Control.